Difference
between the Application
The MA5621 is
used for remote collection and transmission of power system information. In the
up-stream direction, an MA5621 is connected to two Optical
Line Terminals (OLTs) through two Passive Optical Network (PON) ports for
network protection. In thedown-stream direction, it is connected to the Remote
Terminal Unit (RTU), Feeder Terminal Unit (FTU), and Transformer Terminal Unit
(TTU) through the FE and serial ports.
The MA5621A is used for the centralized
collection of power system electrical meter data. In the upstream direction,
the MA5621A is connected to the OLT through the PON port, while in the
downstream direction, it is connected to the concentrator or intelligent
electrical meter through the FE or RS485 serial port.
Difference between the Specifications
Product
|
MA5621
|
MA5621A
|
Dimensions (W x
D x H)
|
235mm x 180mm x 44.4mm
|
250mm x 180mm x 43.6mm
|
Network-Side Port
|
Available
configuration modes:
• 2 x GPON
• 2 x GE (optical)
• 1 x GE (optical) + 1 x GPON
|
Available
configuration mode:
• 1 x GPON
|
User-Side Port
|
4 x GE/FE + 4 x RS485/RS232
|
4 x FE + 2 x RS485
|
Working Temperature
|
-40°C to 85°C
|
-40°C to 65°C
|
Ambient Humidity
|
5% Relative Humidity (RH) to 95% RH,
non-condensing
|
5% RH to 95% RH, non-condensing
|
Heat Dissipation Mode
|
Heat is dissipated naturally without
a fan.
|
Heat is dissipated naturally without
a fan.
|
Power Supply
|
AC: 220 V/110 V auto-negotiation
DC: 12 V/24 V/48 V auto-negotiation
|
AC: 220 V/110 V auto-negotiation
|
Weight
|
1.5 kg
|
1.24 kg
|
More related:
No comments:
Post a Comment