Cables for Huawei AR G3 Routers (2)



1E1/T1 Cable

Appearance and Structure

1E1 75-ohm cable



1E1 120-ohm or 1T1 100-ohm cable



Connection

1E1 cables are classified into 75-ohm cables. The connectors of the cables are as follows:
  •         75-ohm cable (DB9 to BNC):
        1.        One end provides a DB9 connector.
        2.         The other end provides two BNC connectors.

  •         120-ohm cable (DB9 to RJ45)
        1.        One end provides a DB9 connector.
        2.        The other end provides an RJ45 connector.

A T1 cable is a T1 100-ohm cable. Its appearance is the same as the appearance of an E1 120-ohm cable.

Trunk cable

NOTE:

The 1E/T1 cable is 3m long. If the connection distance is long, a trunk cable is required.
  •         E1 75-ohm trunk cable: BNC to BNC (The two connectors are BNC 75 angle male-‖.)
  •         E1 120-ohm or T1 100-ohm trunk cable: RJ45 (The two connectors are RJ45.)

The E1 75-ohm trunk cable is connected as follows:

  •         If the 1E1 cable extension is not used, the BNC connector is connected to the remote device.
  •         If the 1E1 cable extension is used, the BNC connector is connected to a coaxial connector, and the coaxial connector is connected to the remote device through the trunk cable.

The E1 120-ohm or T1 100-ohm trunk cable is connected as follows:

  •         If the 1E1/T1 cable extension is not used, the RJ45 connector is connected to the RJ45 interface of the remote device.
  •         If the 1E1/T1 cable extension is used, the RJ45 connector is connected to a network interface connector, and the network interface connector is connected to the remote device through the trunk cable.

4E1/T1 Cable
 
Appearance and Structure

4E1 75-ohm cable


4E1 120-ohm cable



Connection

4E1/T1 cables are classified into 75-ohm cables and 120-ohm cables. The connectors of the cables are as follows:
  •         75-ohm cable (RJ45 to BNC):
         1.        One end provides a RJ45 connector.
         2.        The other end provides two BNC connectors.

  •         120-ohm cable (RJ45 to RJ45):
         1.        One end provides a RJ45 connector.
         2.        The other end provides an RJ45 connector.

Trunk cable

NOTE:

The 4E1/T1 cable is 3m long. If the connection distance is long, a trunk cable is required.
  •         E1 75-ohm trunk cable: BNC to BNC (The two connectors are BNC 75 angle male-‖.)
  •         E1 120-ohm trunk cable: RJ45 to RJ45 (The two connectors are RJ45.)

The E1 75-ohm trunk cable is connected as follows:

  •         If the 4E1 cable extension is not used, the BNC connector is connected to the remote device.
  •         If the 4E1 cable extension is used, the BNC connector is connected to a coaxial connector, and the coaxial connector is connected to the remote device through the trunk cable

The E1 120-ohm trunk cable is connected as follows:

  •         If the E1 cable extension is not used, the RJ45 connector is connected to the RJ45 interface of the remote device.
  •         If the E1 cable extension is used, the RJ45 connector is connected to a network interface connector, and the network interface connector is connected to the remote device through the trunk cable

Synchronous/Asynchronous Serial Cable

Synchronous/Asynchronous Serial Cables


Connection

A synchronous/asynchronous serial cable is connected as follows:

  •         The DB28 connector is connected to a DB28 port on a card.
  •         Connection of the other end depends on the type of the WAN link:
           1.        If WAN link is a digital data network (DDN) line, connect the other end of the cable to a port on a channel service unit (CSU) or data service unit (DSU).
           2.        If the WAN link is a dial-up line, connect the other end of the cable to the serial port on a modem.